VAPOUR HEADER DIA FOR PAN SECTION
S.No
Description
Value
UOM
1
Crushing Rate
TCH
2
A m/c % cane
home:
Take percentage of m/c boiled on that particular vapour (Ex: If we boiled 50% m/c on 2nd vapour than calculating the 2nd vapour header take 50% m/c value on total m/c percent)
%
3
B m/c % cane
home:
Take percentage of m/c boiled on that particular vapour (Ex: If we boiled 100% m/c on 3rd vapour than calculating the 2nd vapour header take value zero here)
%
4
C m/c % cane
home:
Take percentage of m/c boiled on that particular vapour (Ex: If we boiled 100% m/c on 2nd vapour than calculating the 3rd vapour header take value zero here)
%
5
Temperature of input vapour
o
C
6
Velocity of input vapour
m/sec
7
Specific steam consumption for A massecuite (Take maximum requirement)
Ton of vapour/ ton of massecuite
8
Specific steam consumption for B massecuite (Take maximum requirement)
Ton of vapour/ ton of massecuite
9
Specific steam consumption for C massecuite (Take maximum requirement)
Ton of vapour/ ton of massecuite
10
Specific volume of Pan inlet vapour
M
3
/kg
Result
Dia of the vapour Header
home:
Taken 10% extra on required vapour
mm
Say
mm
www.sugarprocesstech.com
Thank You for Using Calculator
sugarprocesstech
It is a On-line calculator allowing for evaluating only. If you will give input values in yellow colour cells than you will get remaining values automatically. It also provided print option as well as reset options
Do not show next time
Update
Reset
Print
Submit